model HTQF/3L-0.4/xxxA 3P3L HTQF/4L-0.4/xxxA 3P4L feature   Apply to 3P3L system Apply to 3P4L system, can realize netral line...
  • Hoteam
  • HTQF 3L-0.4/30A-600A
  • US $1,000 - 100,000 | Get Latest Price
  • wooden box with inner plastic bag
  • 20-35days (according to the situation)
  • L/C,D/P,T/T
  • 300 Set/Sets per Month
  • Shandong, China (Mainland)
Product Groups

tommy liu

Mobile :

Tel : 86-531-82670172

Request a quote

Address:Hoteam building, No.2600, Yingxiu Road, High-tech district, Jinan, China

Product Details

PlaceofOrigin:Shandong,China(Mainland) BrandName:Hoteam
ModelNumber:HTQF3L-0.4/30A-600A wiringmode:3phase3wire/4wire
ratedvoltage:400V-20/+15%(canbedesigned) ratingcompensationcurrent(A):30A-600A(canbedesigned)
ratingcompensationcapacity(Kvar):20Kvar-400Kvar(canbedesigned) externaldimmension(mm)W*D*H+Plinth:600*400*1300+200(canbedesigned)
RE.weight(kg):90(canbedesigned) installation:wall-hangingorland-fall
cabinet:MNSorGGD color:RAL7035(canbedesigned)
IPdegree:40-54(canbedesigned)

Product Description

model

HTQF/3L-0.4/xxxA3P3L

HTQF/4L-0.4/xxxA3P4L

feature

 

Apply to 3P3L system

Apply to 3P4L system, can realize netral line filter

input

voltage

400/600V     —15/+10%

400/600V     —15+10%

frequency

50/60HZ ±5%

50/60HZ ±5%

Performance index

Filter capacity

Can be more than 97%

Can be more than 97%

Filter range

2~50th harmonic

2~50th harmonic

Response time

Transient response<0.1ms,

complete response<20ms

Transient response<0.1ms,

complete response<20ms

Neutral line compensate ability

3 times in line RMS current

Reactive power compensation

Setting range of power factor is from inductive0.6 to capacitive 0.6

Setting range of power factor is from inductive0.6 to capacitive 0.6

Balance compensation

Programmable balance of power

 

Programmable balance power of phase and phase or phase and neutral line

Overload protection

Automatic current limiting when 100% rating output

Automatic current limiting when 100% rating output

Power loss

≤3% rated compensation capacity

≤3% rated compensation capacity

configuration

Unit operation

allow

allow

Parallel operation

10 sets at most

10 sets at most

IP

IP3X,(higher IP pls contact manufactuer)

IP3X,(higher IP pls contact manufactuer)

Environment condition

temperature

—10~40°C

—10~40°C

Storage temperature

—25~55°C

—25~55°C

Relative humidity

Max 95%RH(no condensation)

Max 95%RH(no condensation)

altitude

1000m

1000m

Related Products

Shandong Hoteam Electric Co.,Ltd.
Website : www.cnpqsolution.com
Telephone : 86-531-82670172
Mail : tommy@unxinindustry.com
Fax : 86-531-82670072
Address : Hoteam building, No.2600, Yingxiu Road, High-tech district, Jinan, China

Copyright © 2017 - 2020Shandong Hoteam Electric Co.,Ltd. All Rights Reserved