English
Home >  Active Harmnoic Filter >  advanced harmonic protection device
advanced harmonic protection device

advanced harmonic protection device

Specifications harmonic protection device ripple cross technology strict thermal design integrated function USA...
  • Hoteam
  • US $1,000 - 100,000/ Set | Get Latest Price
  • 45 working days
  • paypal,UnionPay, Visa/MasterCard, Amex, Discover,T/T
  • 500 Set/Sets per Month
  • Shandong, China (Mainland)
Product Groups

tommy liu

Mobile :

Tel : 86-531-82670172

Request a quote

Address:Hoteam building, No.2600, Yingxiu Road, High-tech district, Jinan, China

Product Details

Place of Origin:Shandong, China (Mainland) Brand Name:Hoteam
Model Number:HTQF series rating compensation current:30~600A
mains voltage:400V-20/+15% mains frequency:50/60Hz+/-5%
filter range:2~50th filter frequency:>97%
IP:IP40 response time:Complete response<20ms
power loss:<3% rating compensation capacity storage temperature:-25~70'C
serving temperature:-10~40'C

Product Description

Specifications

harmonic protection device
ripple cross technology
strict thermal design
integrated function
USA control chip

harmonic protection device

 

Introduction of Functions

Harmonic Filter: HTQF is composed of command current computing circuit and compensation current generating circuit. Command current computing circuit conducts real-time monitoring of current in circuit; switch the analogue current signals into digital signals, and send the signals into DSP for handling; separate harmonics and fundamental wave, send drive pulse in form of PWM signals to compensation current generating circuit; drive IGBT power module, produce compensation current input network which has the same amplitude as harmonic amplitude and inverse polarity; compensate or balance out harmonic current, eliminate power harmonics actively, and thus realize the dynamic quick and complement treatment of power harmonics.

Dynamic reactive power compensation: While filtering harmonics, according to detected need for reactive power compensation, HTQF command current computing circuit can control internal capative and inductive fundamental current of compensation current generating circuit, conduct real-time compensation, set the target value of reactive power compensation through operation board. There are 4 working modes for choice, namely, “filter priority”, “reactive power priority”, “harmonic filter only”, “and reactive power compensation only”. The working mode should be selected according to specific conditions of power distribution system.

Correct unbalanced 3 phases: HTQF can compensate the unbalanced 3 phases respectively. It can conduct phase adjustment of active power through DC Energy Storage Systems shared by 3 phases, thus to correct unbalanced load of 3 phases. The operation of this function can also be set by operation board.

Special Features

Higher efficiency, lower loss

       Patented technology of ripple cancellation and stagger converter is characterized by high current tracing speed, small ripple and low loss;

   Multi-DSP collaborative control can guarantee highly accurate control and high-speed computation;

   The harmonic filter rate is high. Toward target harmonics, effective harmonic filter rate can reach 97%;

   It can filter up to over 20 kinds of harmonics at the same time, and harmonics in side of the 50th at most

   Low-loss ceramic alloy;

 Magnetic Core reactor is characterized by low noise and high efficiency.

More functions, more modes

  Fractional compensation of harmonics can be set according to actual needs;

  Harmonic reactive compensation is equipped with 4 working modes, namely, “filter priority”, “reactive power priority”, “harmonic filter only”, “reactive power compensation only”, which can satisfy the compensation need for various power distribution systems;

  Balance compensation function can balance the load current among phases;

  RS485 interface, standard MODBUS RTU communication protocol, and computer remote monitoring function.

More stable, more reliable

 Optical fiber drive can guarantee high security, reliability and anti-jamming capability;

Multi-protection, strict thermal design can ensure the secure and reliable operation of the system;

Advanced control algorithms can offer stable operation for various complex environments, and it can also conduct parallel operation with capacitor compensating box;

 Digital control, LCD working platform Chinese;

Self-diagnosis function

Record of historical events function

Higher power density, easier installation and maintenance

 Modular design of converter can guarantee high power density, and easy installation and maintenance;

Output capacity is high. Single-unit output capacity can reach up to 600A;

It can conduct multi-machine parallel operation to satisfy various needs for compensation capacity.

Automatic current limiting will be conducted once output capacity is fully loaded,  so it is free of the trouble in overloading;

Detection methods of source current and load current are optional for the convenience of field installation.

 

 

HTQF technical parameters

model

HTQF/3L-0.4/xxA  3P3L

HTQF/4L-0.4/xxA  3P4L

feature

 

Apply to 3P3L system

Apply to 3P4L system, can realize netral line filter

Compensation current of each cabinet

50A

50A

75A

75A

100A

100A

150A

150A

200A

200A

250A

250A

300A

300A

400A

400A

500A

500A

600A

 

input

voltage

400/600V     -15/+10%

400/600V     -15+10%

frequency

50/60HZ  ±5%

50/60HZ  ±5%

Performance index

Filter capacity

Can be more than 97%

Can be more than 97%

Filter range

2~50th harmonic

2~50th harmonic

Response time

Transient response<0.1ms,

complete response<20ms

Transient response<0.1ms,

complete response<20ms

Neutral line compensate ability

----

3 times in line RMS current

Reactive power compensation

Setting range of power factor is from inductive0.6 to capacitive 0.6

Setting range of power factor is from inductive0.6 to capacitive 0.6

Balance compensation

Programmable balance of power

 

Programmable balance power of phase and phase or phase and neutral line

Overload protection

Automatic current limiting when 100% rating output

Automatic current limiting when 100% rating output

Power loss

≤3% rated compensation capacity

≤3% rated compensation capacity

CT requirements

3set, 0.2magnitude or more,secondary 5A

3set, 0.2magnitude or more,secondary 5A

Current detection means

Source current detection or load current detection

Source current detection or load current detection

Display and interface

language

English/Chinese

English/Chinese

Operating button

Start/stop,reset,menu,confirm,fluctuation function keys and so on

Start/stop,reset,menu,confirm,fluctuation function keys and so on

Indicator light

Green: normal operation

Green: normal operation

Orange: overcurrent/overload operation

Orange: overcurrent/overload operation

Red: machine halt or alarm

Red: machine halt or alarm

Communication interface

RS-485

RS-485

Communication protocol

MODBUS(RTU)

MODBUS(RTU)

digitI/O

4 digital input, 2 digital alarm

4 digital input, 2 digital alarm

configuration

Unit operation

allow

allow

Parallel operation

10 sets at most

10 sets at most

IP

IP3X,(higher IP pls contact manufactuer)

IP3X,(higher IP pls contact manufactuer)

Color

RAL7035(light gray),can be customized according to use requirements

RAL7035(light gray), can be customized according to use requirements

Environment condition

temperature

-10~40°C

-10~40°C

Storage temperature

-25~55°C

-25~55°C

Relative humidity

Max 95%RH(no condensation)

Max 95%RH(no condensation)

altitude

1000m

1000m

 

Related Products

Shandong Hoteam Electric Co.,Ltd.
Website : www.cnpqsolution.com
Telephone : 86-531-82670172
Mail : tommy@unxinindustry.com
Fax : 86-531-82670072
Address : Hoteam building, No.2600, Yingxiu Road, High-tech district, Jinan, China